Flexor Tenorrhaphy Tensile Strength: Reduction by Cyclic Loading
Fanlu Min, 1 , 2 ,Zhanhu Yao, 3 and Teng Jiang 4
Author information Article notes Copyright and License information
Abstract
The dynamic characterization of concrete is fundamental to understand the material behavior in case of heavy earthquakes and dynamic events. The implementation of material constitutive law is of capital importance for the numerical simulation of the dynamic processes as those caused by earthquakes. Splitting tensile concrete specimens were tested at strain rates of 10−7 s−1 to 10−4 s−1 in a material test machine. Results of tensile strength versus strain rate are presented and compared with compressive strength and existing models at similar strain rates. Dynamic increase factor versus strain rate curves for tensile strength were also evaluated and discussed. The same tensile data are compared with strength data using a thermodynamic model. Results of the tests show a significant strain rate sensitive behavior, exhibiting dynamic tensile strength increasing with strain rate. In the quasistatic strain rate regime, the existing models often underestimate the experimental results. The thermodynamic theory for the splitting tensile strength of concrete satisfactorily describes the experimental findings of strength as effect of strain rates.
1. Introduction
It has long been known that concrete materials have a low tensile strength compared to their compressive strength. Since concrete is inherently weak in tension, it has been used as compressive member material in most concrete structures [1–5]. However, even though static tensile loads on concrete members are avoided, it is difficult to isolate concrete members from dynamic tensile stresses. The propagation of tensile stress wave in structural members is generated by explosives, impingement of projectiles, earthquakes, and so on [6, 7]. In fact, in the Great Hanshin-Awaji Earthquake, some uncommon fractures and damages of concrete structures were observed which might have been caused by the propagation of stress waves and/or interface of tensile stress waves.
At a time when a concrete structure comes under dynamic loading, two different modes of failure should be distinguished: local effects and the global effects on the structure. With the current computational facilities and the knowledge on computational modeling, force and stress distributions can be calculated in concrete structures under complex dynamic loading conditions. However, models for dynamic properties of materials are still in their infancy [8, 9]. Consequently, these material models are the weak link in advanced finite element calculations. Reliable test data, that support modeling, are only available to a limited extent.
The compressive behavior of cement based materials under different strain rates has been studied rather extensively. Results of loading tests have confirmed an increase in compressive strength of concrete subjected to dynamic loading. This general result has been confirmed by many researchers in the course of many decades. Some comprehensive review papers of more recent works on this topic can be found in several surveys. For example, Abrams even in 1917 reported that an increase in the rate of loading was accompanied by an increase in the compressive strength of concrete. The same findings were announced by Wastein [10], and Atchley et al. [11] or Hughes and Watson [12]. But because of difficulties in the test setup and instrumentation, little attempt was made to measure the tensile behavior of cement based materials under dynamic loads and thus little data is available.
Flexor Tenorrhaphy Tensile Strength: Reduction by Cyclic Loading
In Vitro and Ex Vivo Porcine Study
C. E. R. Gibbons,corresponding author3 D. Thompson,2 and M. J. Sandow1
Abstract
The integrity of the repair is critical to maintain coaptation of the severed flexor tendon end until healing has advanced sufficiently. In our hospital, we use a modified Savage repair (four-strand Adelaide technique) using 3–0 Ethibond (Ethicon, Somerville, NJ, USA) for acute flexor tenorrhaphy and an active postrepair mobilization protocol. To explain the apparent differences between the theoretical and actual repair strength of a multistrand repair in a single tension test and the reduced strength of a repair subjected to cyclic loading, we compared single and cyclical tensile loading with different suture in vitro configurations of 3–0 Ethibond (Ethicon, Somerville, NJ, USA; one, two, and four strands) and an ex vivo four-strand repair of freshly divided porcine tendon to calculate the ultimate tensile strength (UTS). Mechanical testing was repeated 15 times with both single tensile and cyclical loading for each suture configuration and porcine repair. In the in vitro model, the presence of a knot in a single strand reduced the UTS by 50%. The stiffness of a knotted strand was substantially less than the unknotted strand but became identical after cyclical loading. There was no statistical significance of the UTS between single and cyclical loading with different numbers of strands in this model. In the ex vivo four-strand porcine repair model, there was a significant reduction in UTS with cyclical loading, which equated to the number of strands times the strength of the knotted strand. This discrepancy can be explained by the change in stiffness of the knotted strand after cyclical loading and has important implications for previous studies of suture tendon repair using single tensile loading where the UTS may have been overestimated. We believe that cyclical loading is more representative of physiological loading after acute flexor tendon repair and should be the testing model of choice in suture tenorrhaphy studies.
Keywords: Flexor, Tenorrhaphy, Cyclic loading, Stiffness
Introduction
Maintaining approximation of the severed flexor tendon ends is critical after repair to achieve healing and there have been multiple techniques and extensive research to identify the optimal tenorrhaphy method [3, 5, 6, 13]. Successful flexor tenorrhaphy can depend on a number of factors including the tensile properties of suture material, integrity of each suture grasp, the type of suture repair, and the surgical expertise available [1, 9, 11, 12]. On the basis of previous research in our unit, we use a four-strand single cross grasp suture repair (Fig. 1) modified from the Savage technique [10], and active mobilization is started as early as possible (either the same day or day after operation) under the care of the physiotherapist.
Figure 1
Illustration demonstrating four-strand Adelaide repair used for flexor tenorrhaphy.
While the in vitro and ex vivo testing of various suture constructs is important to identify the optimal technique, the differences between the theoretical and actual repair strength of a multistrand repair [10] and the apparent reduced strength on a repair subjected to cyclic loading [4, 8] have not been explained by this previous work. Many studies have investigated the mechanical properties of suture repair with single tensile loading [1], but few have compared single tensile and cyclical loading [8].
To investigate these discrepancies, we assessed the mechanical performance of our preferred tenorrhaphy technique during cyclic and static loading in an in vitro and ex vivo situation. The conduct of this study was to firstly analyze, in both single tension and cyclic loading conditions, the mechanical properties of in vitro 3–0 braided polyester suture material (Ethicon, Somerville, NJ, USA) with different strand configurations (single strand without knot, single strand with knot, two strands with knot, and four strands with knot) and then a four-strand ex vivo porcine tendon repair.
Methods
The study was conducted in two parts: Firstly, an in vitro study to test the mechanical performance of the suture material in various configurations and secondly, an ex-vivo study to test the performance of the multistrand repair in an animal tendon model. A Hounsfield mechanical testing machine (Hounsfield H25KM Universal Testing Machine, Hounsfield Testing Equipment Ltd, Surrey, UK; Material Testing System was used to measure stiffness during cyclic loading and ultimate tensile load both for the different suture configurations and the porcine four-strand tendon repairs for both single tensile and cyclical loading tests, with each particular test being repeated 15 times. A standardized technique was used for testing both the suture configurations and tendon repairs, with 3–0 Ethibond (Ethicon, Somerville, NJ) suture. Different configurations of single strand with and without a knot, two strands with a knot, and four strands with a knot were tested.
The suture was attached to the testing apparatus by means of two smooth 1 cm bars, 60 mm apart (Fig. 2). In the tests using a closed loop (i.e., knotted two- and four-strand knotted repairs), the strands were passed around the bars. Where the repairs were not a closed loop (i.e., single strand knotted and unknotted configurations), the free ends of the two end strands were secured to the bar by multiple wrapping and then adhesive tape over the entire wrap (Fig. 3). Preliminary studies showed this technique of fixation achieved no appreciable creep under the testing conditions. A minimum of five square throws were performed to secure the knot where used.
Figure 2
Photograph of a two-strand Ethibond (Ethicon, Somerville, NJ, USA) suture configuration with knot looped around restraining bars of Hounsfield tensile machine.
Figure 3
Illustration demonstrating unknotted and knotted single suture strand between restraining bars.
For the single tensile load testing, the suture configurations were preloaded to one Newton and then a tensile force applied until ultimate failure. Cyclical tensile tests were applied loading at 10 N per strand for ten cycles prior to loading to ultimate failure. This level of submaximal cyclic loading was chosen to eliminate the slack within the knot prior to testing to tensile failure.
It was assumed that at the rate of loading used, the viscoelastic effect is negligible. The rate of loading used is best defined as quasistatic and changes within this range have negligible influence on ultimate tensile strength (UTS) and construct stiffness. Testing at 500 mm/s would most likely create different viscoelastic loading effects, but this was not assessed in this study:
In vitro study: The initial study was to assess the in vitro properties of the commonly used tenorrhaphy suture, 3–0 Braided Polyester (Ethibond, Ethicon, Somerville, NJ, USA), when subjected to testing in both single tensile and cyclic loading conditions. A single strand with and without a knot and then two- and subsequently four-strand configurations were tested
Ex vivo study: Thirty porcine forefoot flexor tendons were freshly prepared which were similar in size and appearance to human flexor profundus tendon. The tendons were divided with a sharp blade and a four-strand Adelaide repair performed with 3–0 Ethibond (Ethicon, Somerville, NJ, USA). The tendon ends were attached to securing clamps. Fifteen single and 15 cyclical tests before loading to ultimate tensile strength were then applied under standardized conditions. Using computer software, the results were extrapolated to produce a load displacement curve for each test
The mean of both the in vitro suture tension tests and ex vivo four-strand tendon repairs were calculated. Statistical analysis was applied using the student t test to compare the single and cyclical loading tension tests for each suture configuration or four-strand repair. Using computer software, a curve of best fit for each test of the suture configurations was plotted. This allowed assessment of stiffness of the particular strand configuration by visualization of the slope of the curve at different points. Quantifying the stiffness is achieved by dividing the load by the displacement (N/mm).
Results
Each suture configuration was tested to failure following either a single tension loading or a cyclic loading sequence. In all knotted strands, failure occurred at the site of the knot. Quantifying the stiffness is achieved by dividing the load by the displacement (N/mm). This is simple for linear materials like the unknotted and perfectly secured unknotted strand (i.e., a 5-mm displacement for 10 N load = 2 N/mm); however, when the knot slips, there is a nonlinear and unpredictable initial stiffness. The stiffness is initially low and ramps up to the unknotted equivalent stiffness.
Effect of Knot—Single Strand In Vitro Repair
The mean ultimate tensile load for a single strand 3–0 Ethibond (Ethicon, Somerville, NJ, USA) was 34 N under single tensile loading and 36 N under cyclical loading conditions (n.s. p > 0.05). The presence of a knot with a single strand reduced the ultimate tensile load by approximately 50% (p < 0.05) in both cyclic loading and single tension testing groups (Fig. 4).
Figure 4
Bar chart demonstrating effect of cyclic loading on in vitro strand configurations and four-strand ex vivo porcine repair.
Number of Suture Strands
In both single and cyclical loading tests, increasing the number of strands increased the ultimate tensile load (Table 1). Doubling the suture strand from single strand to double strand with knot and from double strand to four strands with knot slightly more than doubled the ultimate tensile load.
Table 1
Table 1
In vitro 3–0 Ethibond (Ethicon, Somerville, NJ, USA) suture and ex vivo four-strand tendon repair mean ultimate tensile strength (N).
Single Versus Cyclical Loading
All groups were compared with single tensile and cyclical loading. There was no statistical difference found with a single strand, single strand with knot, and double strand with knot with different loading tests. There was a slight decrease in ultimate tensile load in the four-strand group with cyclical loading (Fig. 4), but this was not significant (p > 0.05). With the four-strand tendon (ex vivo) repair, there was a decrease from 80 N in the single tensile loading group to 70 N in the cyclical loading group (p < 0.05).
Stiffness of Single Strand Group
For the single strand configurations (single strand with and without knot), all 15 tests were expressed as a linear line of best fit for a load displacement curve. The relative stiffness of the suture material was represented by the slope of the load displacement curve. It was found that the knotted single strand was less stiff than a single strand (mean stiffness = stiffness value) under tensile loading (p < 0.05; Fig. 5); however, after cyclical loading, the single strand and the single strand with a knot had the same stiffness represented by the same slope on the load displacement graph (Fig. 6).
Figure 5
Load displacement curve demonstrating effect of single tensile loading on unknotted and knotted single suture strand.
Figure 6
Load displacement curve demonstrating effect of cyclic loading on unknotted and knotted single suture strand.
Variance in Mean Ultimate Tensile Strength
There was found to be less variance in ultimate tensile load with cyclical loading in all groups (Table 1).
Discussion
An active postrepair mobilization protocol places increasing stresses on the suture construct as it is the suture material itself which maintains the integrity of the tendon repair until the healing is sufficiently advanced. In an effort to improve the ultimate mechanical strength of repairs, multistrand techniques have been introduced. To identify the best suture materials for tendon repair, in vitro and ex vivo studies of suture ultimate tensile strength of different techniques of acute flexor tenorrhaphy have previously been described [1, 2, 7, 9, 11, 12].
In the first part of this study, the mechanical strengths of different numbers of strands of suture material was reviewed. Savage [9] has previously shown the weakest area being at the site of a knot. This was confirmed in our study which showed the ultimate tensile strength of a single suture strand to be reduced by approximately 50% with the presence of a knot (Fig. 6). Savage and Rositano [10] also suggested that in a multistrand repair in a frictionless environment, each strand should share the load and the construct should fail once the weakest strand (i.e., the knotted strand) has exceeded its ultimate tensile. Previous studies [8, 10] have documented a discrepancy of this simple arithmetic formula (strength of the weakest (knotted) strand times the number of strands) with a higher measured UTS on single tension testing being attributed to some form of friction in the experimental system. Aoki et al. identified that the tensile strength of a tenorrhaphy following cyclic loading was less than the same repair under single tension testing loads. Again, the difference is attributed to the effects of friction in the testing system.
Our study, however, suggests that the discrepancy in the UTS of the multistrand repair between single tension and cyclic loading can be explained by the behavior of the knot during initial and subsequent loading. The load displacement curves for a knotted and unknotted strand for both single tensile and cyclical loading (Figs. 5 and and6)6) were compared. It was clear that the stiffness of the knotted strand was substantially less than the unknotted strand (represented by the slope of the curve) for a single tensile test. After cyclical loading, the stiffness of the knotted strand was identical to that of the unknotted strand, but the UTS remained the same being 50% weaker in the presence of a knot.
This study has not investigated the presence of grasp migration or the viscose elastic deformation of 3–0 Ethibond (Ethicon, Somerville, NJ, USA) which contribute to differences in the mean UTS between the in vitro and ex vivo four-strand models. The main difference can be attributed to the effect of friction combined with the variation in stiffness of the knotted and unknotted strands in the testing model.
We conclude that the UTS of a given knotted length of suture will be constant, regardless of single or cyclic loading. However, the knotted strand is both the weakest and has a lower stiffness (during initial loading) than other strands in a multistrand repair. During single tension testing, if the strands of a repair cannot undergo immediate equilibration due to friction, a lower knotted strand stiffness is evident and this leads to delayed rate of loading until maximum loading and ultimate failure when compared to the loading of the stiffer unknotted strands. This in turn leads to an incorrectly elevated estimate of the likely UTS. This discrepancy can be addressed by cyclic loading of the construct which maximizes (or normalizes) the stiffness of the knotted strand. This change in the knotted systems stiffness occurs because slack within the knot cannot be completely removed by hand during construction and is removed during initial tensile loading. This removal of slack within the knot during the initial loading phase produces a reduction in system stiffness until a point where the slack is completely removed. At this point, the knotted system will exhibit identical stiffness to an unknotted system; however, the knotted system will fail at significantly lower UTS due to the knot acting as a ‘stress raiser’.
These findings are clinically important because slack within the knot could tighten causing a gap between tendons. The magnitude of the gap would be minimized with increasing numbers of strands. Cyclical mechanical loading is a more exacting technique and more closely reproduces physiological loading of a flexor tendon repair which has important clinical implications for previous studies concerning strength of tendon repair. We therefore recommend the use of cyclical mechanical testing techniques in the future study of tendon repair techniques as single tensile testing of tendon repairs may give falsely generous results with regards to UTS. Removing the slack from the knot within the knotted system allows more accurate measurement of the ultimate system strength and stiffness.
References
1. Aoki M, Pruitt DL, Kubota H, Mankse PR. Effect of suture knots on tensile strength of repaired flexor tendons. J Hand Surg [Am] 1995;1B:72–5. [PubMed]
2. Bowyer M, Gelberman RH, Burns ME, et al. Intrasynovial flexor tendon repair. J Bone Jt Surg 2001;83A:891–8. [PubMed]
3. Elliot D, Moiemen NS, Flemmings AF, et al. The rupture rate of acute flexor tendon repairs mobilized by the controlled active motion regimen. J Hand Surg [Am] 1994;19B:607–12. [PubMed]
4. Hannafin JA, Arnoczky SP, Hoonjan A, et al. Effect of stress deprivation and cyclic tensile loading on the material and morphologic properties of canine digitorum profundus tendon; an in vitro study. J Orthop Res 1995;13:907–14. doi:10.1002/jor.1100130615. [PubMed]
5. Kleinert HE, Kutz JE, Atosoy E, Stormo A. Primary repair of flexor tendons. Clin Orthop 1973;4:865–76. [PubMed]
6. Lister GD, Kleinert HE, Kutz JE, Attasoy E. Primary flexor tendon repair followed by immediate controlled mobilisation. J Hand Surg [Am] 1977;2A:441–51. [PubMed]
7. Matheson G, Nicklin S, Gianoutsous, et al. Comparison of zone II flexor repairs using an in-vitro linear cyclic testing protocol. Clin Biochem 2005;20:718–22. [PubMed]
8. Pruitt DL, Manske P, Fink B. Cyclic stress analysis of flexor tendon repair. J Hand Surg [Am] 1991;16A:701–7. doi:10.1016/0363-5023(91)90197-J. [PubMed]
9. Savage R. In vitro studies of a new method of flexor tendon repair. J Hand Surg [Am] 1995;10B:135–41. [PubMed]
10. Savage R, Rositano G. Flexor tendon repair using a six strand method of repair and early active mobilisation. J Hand Surg [Am] 1989;14B:396–9. [PubMed]
11. Shaieb MD, Singer DI. Tensile strengths of various suture techniques. J Hand Surg [Am] 1997;6B:764–7. [PubMed]
12. Silfverskiold KL, May EJ. Flexor tendon repair in zone II with a new suture technique and an early mobilization program combining passive and active flexion. J Hand Surg [Am] 1994;19A:53–60. doi:10.1016/0363-5023(94)90224-0. [PubMed]
13. Strickland JW, Glogovac SV. Digital function following flexor tendon repair in zone II: a comparison of immobilization and controlled passive motion techniques. J Hand Surg [Am] 1980;5A:537–43. [PubMed]
Articles from Hand (New York, N.Y.) are provided here courtesy of American Association for Hand Surgery